Feature
●Current Rating:1A
●Voltage-Time:23uS
●Switching Frequency:150KHZ min
●11 mm min creepage and clearance distance between PRI&SEC
●Coplanarity:0.1[.004]Max
●Designed to comply with the following requirements as defined by IEC60601-1(ed):
●Amendment 1:Providing two means of patient Protection up to a working voltage of 360Vac
●Complies with the following requirements as defined by
●IEC60950-1,EN60950-1,UL60950-1/CSA60950-1 and AS/NZS60950-1
●-Reinforced insulation for a primary circuit at a working voltage of 550Vac
Overvoltage category II,Pollution Degree 2,up to 2km above sea level
Designed to comply with the following requirements as defined by IEC60664-1:
●-Reinforced insulation for a primary circuit at a working voltage of 400Vac
up to 2km above sea level.
Designed to comply with the following requirements as defined by IEC61010-1:
●-Reinforced insulation for a line to neutral voltage up to 1000vrms,overvoltage Category II,up
to 2km above sea level
●- Reinforced insulation for a line to neutral voltage up to 600vrms,overvoltage Category II,up
to 5km above sea level
Complies with the following requirements as defined by IEC62368-1,UL/CSA62368-1 and
EN62368-1
●- Reinforced insulation for ES3,operating frequency above 30KHZ,working voltage up to
550Vrms,1600Vpeak,overvoltage category II,Pollution Degree II,and up to 2km above sea
level
Comply with RoHS requirements.
Operating temperature range:-40℃ to +125℃.
Qualified to AEC-Q200
Electrical Specifications @ 25℃
|
PAPAMETER
|
TEST CONDITIONS
|
VALUE
|
|
D.C.RESISTANCE 1-3
|
@20C
|
0. 15ohms max
|
|
D.C.RESISTANCE 6-4
|
@20C
|
0. 15ohms max
|
|
INDUCTANCE 1-2
|
100KHZ 10 mVac. LS
|
110 uH min
|
|
INDUCTANCE 2-3
|
100KHZ 10 mVac. LS
|
110 uH min
|
|
CAPACITANCE 1-6
|
100KHZ 10 mVac. CS
|
18pF max
|
|
DIELECTRIC 1-6
|
6250Vrms 2 seconds
|
5000Vrms ,1 minute
|
|
TURNS RATIO
|
6-4:1-3
|
1:1 ±2%
|